Diesel Generator Set

RatingUnitValue
StandbykVA330
StandbykW264
PrimekVA300
PrimekW240
FrequencyHz60
VoltageV220/380
Rated speedrpm1800

Temperature (Celsius) Derate Curves — Unit: kVA

Temperature25°C30°C35°C40°C45°C55°C60°C
kVA330330330330325320315

Altitude (meters) Derate Curves — Unit: kVA

Altitude0 m500 m1000 m1500 m2000 m2500 m3000 m
kVA330330330330323290264

Standard reference Conditions:

Standard reference condition 25℃ (77℉) air inlet temp, 100m (328ft) A.S.L 30% relative humidity. Fuel consumption data with diesel fuel with specific gravity of 0.85 and conforming to BS 2869: 1998, Class A2.

Note:

The standby power rating of the generating set is where a variable load limited to an annual usage up to 500 hours is applied, with 300 hours of which may be continuous running. Noting that no overload is permitted.

Standard Features •  The generator set and its components are prototype-tested, factory-built, and production-tested. •  The generator set complies with ISO 8528-5, Class G3 requirements for transient performance. •  The generator set accepts rated load in one step. •  The 60Hz generator set engine is certified by the Environmental Protection Agency (EU or MEP) to conform to EU2、EU3 nonroad emissions regulations. (≤560KW) •  A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available.Generator Features •  The brushless, rotating-field generator has broadrange reconnectability. •  The pilot-excited, permanent-magnet generator (PMG) provides superior short-circuit capability. •  Controllers are available for all applications. See controller features inside. •  The low coolant level shutdown prevents overheating (standard on radiator models only). •  Integral vibration isolation eliminates the need for under-unit vibration spring isolators. •  An electronic, isochronous governor delivers precise frequency regulation. •  Electronic engine controls and a generator microprocessor controller combine to deliver one of the most advanced control systems in today’s generator market.
Engine Specifications
Manufacturer / ModelCummins 6LTAA9.5-G3
Cylinder No.& Configuration6 cylinder Diesel L type
Working ModeTurbocharged and air-cooled charge air
Bore x Stroke116.5*148mm
Displacement9.5L
Compression Ratio16.6:1
Rated Power265kW
Rated Speed1800
Lubrication SystemSplash Lubrication
Lube OilConforms above CF class or SAE10W-30,15w-40
Lube Oil Capacity32.4L
Battery Capacity6-QW-80(600)*2
Fuel TypeDiesel:0#(Summer),-10#(Winter),-35#(Cold)
Fuel Consumption 25% load18L/H
Fuel Consumption 50% load33L/H
Fuel Consumption 75% load47L/H
Fuel Consumption 100% load65L/H
ALTERNATOR SPECIFICATION
Type4-Pole, Rotating-Field
Exciter typeBrushless, Permanent-Magnet, Pilot Exciter
Voltage regulatorSolid-State, Volts/Hz
InsulationNEMA MG1, Class H
MaterialSynthetic, Nonhygroscopic
Temperature risePrime 130℃, 150℃ Standby
Bearing: quantity, type1, Sealed
CouplingFlexible Disc
Amortisseur windingsFull
Rotor balancing125% 60 Hz, 150% 50 Hz
Voltage regulation, no-load to full-load (with < 0.5% drift due to temp. variation)3-Phase Sensing, ±0.25%
One-step load acceptance100% of Rating
Unbalanced load capability100% of Rated Standby

Features

•  NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting.

•  Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.

•  Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the generator field.

•  Self-ventilated and dripproof construction.

•  Superior voltage waveform from two-thirds pitch windings and skewed stator.

•  Digital solid-state.volts-per-hertz voltage regulator with±0.25% no-load to full-load regulation.

•  Brushless alternator with brushless pilot exciter for excellent load response.

Controller

Audiovisual annunciation with NFPA 110 Level 1 capability. Programmable microprocessor logic and digital display features.

Safeguard circuit protection standard.

12- or 24-volt engine electrical system capability.

Remote start, remote annunciation, and remote communication options. Refer to M6-46 for additional controller features and accessories.

Key Features

•  4-line back-lit LCD text display•  Charger alternator failure alarm
•  Five key menu navigation•  Manual speed control
•  Front panel editing with PIN protection•  Manual fuel pump control
•  LED and LCD alarm indication•  Engine exerciser
•  Customisable status screens•  “protections disabled” feature
•  Power save mode•  kW overload protection
•  Support for up to three remote display units•  Power monitoring
•  9 configurable inputs•  Load switching (load shedding and dummy load outputs)
•  8 configurable outputs•  Automatic load transfer
•  Flexible sender inputs•  Unbalanced load protection
•  Configurable timers and alarms•  Independent Earth Fault trip
•  3 configurable maintenance alarms•  USB connectivity
•  Multiple date and time scheduler•  Backed up real time clock
•  Configurable event log (250)•  Configurable display languages
•  Control logic facilities•  User selectable RS232 and RS485 communications
•  Easy access diagnostic page•  SMS Messaging (additional external modem required)
•  CAN and Magnetic Pick-up / Alt. Sensing•  Additional display screens to help with modem diagnostics
•  Fuel usage monitor and low fuel alarms•  Integral PLC editor
Generating Sets Standard and Optional Features
Engine•  4-stroke, water-cooled diesel engine •  Standard air filter •  Standard fuel filter •  Standard oil filter •  Oil temperature sensor •  Low coolant level sensor •  Radiator with blowing fan •  Industrial Grade Silencer •  Fuel water separator •  Water jacket heater (optional)
Alternator•  Class H insulation •  IP23 Protection •  Automatic Voltage Regulator (AVR) •  PMG excitation (optional) •  Single bearing alternator •  Class F or class B temperature rise (optional) •  Digital Voltage Regulator (optional) •  Double bearing (optional) •  Anti-Condensation Heater (optional) •  IP41 Protection (optional)
Electrical system•  Maintenance-free and anti-explosion battery •  Standard breaker •  ABB breaker (optional) •  ATS (optional) •  Battery charger (optional) •  GMS monitoring (optional)
Packing•  Engine manual •  Alternator manual •  Gensets operation and maintenance manual •  Tool kit
Baseframe•  Forklift pockets •  Pulling slots •  Earth wire protection •  Built-in anti vibration mountings •  Fuel outlet value •  Standard fuel tank •  Enlarged fuel tank (optional) •  Separated fuel tank (optional)
Canopy•  Weatherproof & sound-attenated canopy •  Sound-absorbing material •  Lifting lug •  Emergency stop button •  Inside silencer

Overview Dimension & Weight

(Silent type)

ConfigurationL= Length (mm)W= Width (mm)H= Height (mm)Weight (kg)Fuel Tank Capacity(L)
Silent Type3910133221002930760

(Open type)

ConfigurationL= Length (mm)W= Width (mm)H= Height (mm)Weight (kg)Fuel Tank Capacity(L)
Open Type3200115018002105400